Skip to main content
Vario 400 SeriesGasVG415215AU
1 / 14
Photo Nr. 1 of the product VG415215AU
Photo Nr. 2 of the product VG415215AU
Photo Nr. 3 of the product VG415215AU
Photo Nr. 4 of the product VG415215AU
Photo Nr. 5 of the product VG415215AU
Photo Nr. 6 of the product VG415215AU
Photo Nr. 7 of the product VG415215AU
Photo Nr. 8 of the product VG415215AU
Photo Nr. 9 of the product VG415215AU
Photo Nr. 10 of the product VG415215AU
Photo Nr. 11 of the product VG415215AU
Photo Nr. 12 of the product VG415215AU
Photo Nr. 13 of the product VG415215AU
Photo Nr. 14 of the product VG415215AU
Photo thumb Nr. 1 of the product VG415215AU
Photo thumb Nr. 2 of the product VG415215AU
Photo thumb Nr. 3 of the product VG415215AU
Photo thumb Nr. 4 of the product VG415215AU
Photo thumb Nr. 5 of the product VG415215AU
Photo thumb Nr. 6 of the product VG415215AU
Photo thumb Nr. 7 of the product VG415215AU
Photo thumb Nr. 8 of the product VG415215AU
Photo thumb Nr. 9 of the product VG415215AU
Photo thumb Nr. 10 of the product VG415215AU
Photo thumb Nr. 11 of the product VG415215AU
Photo thumb Nr. 12 of the product VG415215AU
Photo thumb Nr. 13 of the product VG415215AU
Photo thumb Nr. 14 of the product VG415215AU
Photo thumb Nr. 1 of the product VG415215AU
Photo thumb Nr. 2 of the product VG415215AU
Photo thumb Nr. 3 of the product VG415215AU
Photo thumb Nr. 4 of the product VG415215AU
Photo thumb Nr. 5 of the product VG415215AU
Photo thumb Nr. 6 of the product VG415215AU
Photo thumb Nr. 7 of the product VG415215AU
Photo thumb Nr. 8 of the product VG415215AU
Photo thumb Nr. 9 of the product VG415215AU
Photo thumb Nr. 10 of the product VG415215AU
Photo thumb Nr. 11 of the product VG415215AU
Photo thumb Nr. 12 of the product VG415215AU
Photo thumb Nr. 13 of the product VG415215AU
Photo thumb Nr. 14 of the product VG415215AU

400 series Vario gas cooktop 38 cm Natural gas 10 mbar
VG415215AU

Find a local Dealer

Vario gas cooktop 38 cm Natural gas 10 mbar

Highlights

Special Features

Full electronic power level regulation on 12 levels
Can be combined perfectly with other Vario appliances of the 400 series

Specifications

Three-ring burner with up to 5 KW
Full electronic power level regulation on 12 levels
Precision crafting of 3 mm stainless steel
For surface mounting with a visible edge or for flush mounting
Precise and reproducible flame size
Automatic fast ignition, electronic flame monitoring with automatic re-ignition
Simmer function for cooking on a very low output level
Can be combined perfectly with other Vario appliances of the 400 series
1 multi-ring wok burner with 18 Mj/h, suitable for pots up to max. ΓΈ 32 cm.
Control knobs with illuminated ring, cooking zone and output level markings.
One-handed operation.
Full electronic control in 12 output levels for exact power level regulation plus simmer function.
Automatic fast ignition.
Simmer function.
Cast iron pan support with flat, continuous pot surface.
Brass burner ring(s).
Electronic flame monitoring with automatic re-ignition.
Residual heat indicator.
Safety shut-off.
Depending on the type of installation (surface-mounted or flush-mounted, with or without an appliance cover), the specific location of the cut-out and the knob positions may vary.
The drawing "Installation of the control knob" must be observed if the panel is more than 23 mm thick (there must be a recess at the rear).
If combining several Vario appliances of the 400 series, a connection strip VA 420 must be placed between the appliances. Depending on the type of installation, the corresponding connection strip must be provided.
The bearing capacity and stability, in the case of thin worktops in particular, must be supported using suitable substructures. Take into account the appliance weight and additional loads.
Additional instructions for flush mounting:
Installation is possible in worktops made of stone, synthetics or solid wood. Heat resistance and watertight sealing of the cut edges must be observed. Concerning other materials please consult the worktop manufacturer.
The groove must be continuous and even, so that uniform placing of the appliance on the gasket is ensured. Do not use discontinuous lining.
The joint width may vary due to size tolerances of the combinations and of the worktop cut-out.
If installing several appliances in individual cut-outs allow for a division bar of minimum 50 mm between the individual cut-outs.
Special nozzles can be ordered as spare parts.
Plan for an electrical connection (the appliance is not operable without power supply).
Air intake from above.
No intermediate shelf required.
Rear panel and wall trims must be heat-resistant and consist of a non-flammable material.
A minimum clearance of at least 150 mm from adjacent heat-sensitive furniture or contact surfaces must be observed or thermal insulation fitted.
If operated next to the downdraft ventilation VL 414, the ventilation moulding AA 414 is recommended to ensure maximum performance of the cooktop.
With a total connected load of more than 39.6 MJ/h local regulations concerning room ventilation, room size and combination of extraction or recirculation hoods must be observed. Minimum clearance between gas cooktop(s) with more than 39.6 MJ/h (11kW) and ventilation hood 70 cm.
The minimum distance between the cooktop surface and a cabinet above, out of combustible material, needs to be 70 cm.
The minimum distance to a ventilation above is shown at the planning hints for the individual ventilation product.
Appliance can be snapped into the worktop from above.
Appliance weight: approx. 14.
Total connected load gas 18.0 MJ/h
Total connected load electric 15.0 W.
Connecting cable 1.4 m with plug.

Manual and Documents

Helpful Links

Accessories

Highlights
Special Features
Specifications
Manual and Documents
Accessories